NAME
esm
—
Dell Embedded Server
Management
SYNOPSIS
esm0 at mainbus?
DESCRIPTION
The esm
driver provides support for the
monitoring of the environmental sensors present in a variety of Dell
servers. The hardware monitoring is accessed via the
hw.sensors
sysctl(8)
variable.
Devices compatible with the esm
driver can
provide an arbitrary set of sensors which may include the following
types:
Sensor | Units |
temperature |
uK |
fan |
RPM |
volts |
uVDC |
Sensor data is updated every 10 seconds.
The Embedded Server Management framework has been replaced in more recent Dell systems with the Intelligent Platform Management Interface. Servers using the Intelligent Platform Management Interface may be monitored by the ipmi(4) driver.
WATCHDOG
ESM provides watchdog(4) timer functionality. Once configured, if the watchdog is not reset within a certain period of time, it will timeout and the server will reset. The reset will occur regardless of the recoverability of the hang or crash.
Example of enabling a watchdog:
# sysctl
kern.watchdog.period=10
In this case if the watchdog is not reset, it'll reboot the server after roughly 10 seconds.
Example of disabling the watchdog:
# sysctl
kern.watchdog.period=0
SEE ALSO
HISTORY
The esm
driver first appeared in
OpenBSD 3.9.
AUTHORS
The esm
driver was written by
Jordan Hargrave
<[email protected]>
and
David Gwynne
<[email protected]>.